Effects of cell saver autologous blood transfusion on blood loss and homologous blood transfusion requirements in patients undergoing cardiac surgery on- versus off-cardiopulmonary bypass: a randomised trial

Eur J Cardiothorac Surg. 2006 Aug;30(2):271-7. doi: 10.1016/j.ejcts.2006.04.042. Epub 2006 Jul 7.

Abstract

Objective: Off-pump CABG is potentially associated with reduced intraoperative blood loss and homologous blood transfusion in comparison to on-pump CABG. In this randomised controlled study we investigated the effects of autologous cell saver blood transfusion on blood loss and homologous blood transfusion requirements in patients undergoing CABG on- versus off-CPB.

Methods: Eighty patients were randomised into one of four groups: (A) on-CPB with cell saver blood transfusion (CSBT), (B) on-CPB without CSBT, (C) off-pump with CSBT and (D) off-pump without CSBT. Volume of intraoperative autologous blood transfusion, postoperative mediastinal blood loss and homologous blood transfusion requirements were measured. Homologous blood was transfused when haemoglobin concentration fell below 8 g/dl postoperatively. Pre- and postoperatively prothrombin time and partial thromboplastin time were measured.

Results: Preoperative patient characteristics were well matched among the four groups. The amount of salvaged mediastinal blood available for autologous transfusion was significantly higher in the on-pump group (A) compared to the off-CPB group (C) (433+/-155 ml vs 271+/-144 ml, P=0.001). Volume of homologous blood transfusion was significantly higher in group B vs groups A, C and D (595+/-438 ml vs 179+/-214, 141+/-183 and 230+/-240 ml, respectively, P<0.005). The cell saver groups (A and C) received significantly less homologous blood than the groups without cell saver (160+/-197 ml vs 413+/-394 ml, respectively, P<0.005). Patients undergoing off-CPB surgery received significantly less homologous blood than those undergoing on-CPB CABG irrespective of cell saver blood transfusion (184+/-214 ml vs 382+/-397 ml, P<0.05). Postoperative blood loss was similar in the four groups (842+/-276, 1023+/-291, 869+/-286 and 903+/-315 ml in groups A to D, respectively, P>0.05). Clotting test results revealed no significant difference between the groups. There was no significant difference in postoperative morbidity between groups.

Conclusion: Off-pump CABG is associated with significant reduction in intraoperative mediastinal blood loss and homologous transfusion requirements. Autologous transfusion of salvaged washed mediastinal blood reduced homologous transfusion significantly in the on-CPB group. Cell saver caused no significant adverse impact on coagulation parameters in on- or off-CPB CABG. Postoperative morbidity and blood loss were not affected by the use of CPB or autologous blood transfusion. We recommend the use of autologous blood transfusion in both on- and off-pump CABG surgery.

Publication types

  • Randomized Controlled Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Blood Loss, Surgical / physiopathology
  • Blood Loss, Surgical / prevention & control*
  • Blood Transfusion, Autologous / methods*
  • Cardiopulmonary Bypass*
  • Coronary Artery Bypass / adverse effects
  • Coronary Artery Bypass / methods*
  • Coronary Artery Bypass, Off-Pump
  • Female
  • Hemoglobins / metabolism
  • Hemostasis, Surgical / methods
  • Humans
  • Intraoperative Care / methods
  • Male
  • Middle Aged
  • Partial Thromboplastin Time
  • Postoperative Period
  • Prothrombin Time

Substances

  • Hemoglobins